Qiaofa Machinery Manufacturing Co., Ltd., as an industry-leading steam system solutions expert, is committed to providing customers with premium Pneumatic Condensate Pump - SP5T products and professional services. With mature production processes and a comprehensive technical support system, we offer precise product selection recommendations and customized solutions tailored to actual operating conditions.

We adhere to customer-oriented principles and drive innovation through technology, providing comprehensive services from product selection to technical consultation, helping enterprises enhance steam system efficiency and create greater value.

Detailed Introduction

PNEUMATIC CONDENSATE RECOVERY PUMP

Basic knowledge

    WDV20 condensate water automatic pump belongs to a sort of pressure control pump,designed for the occasion where condensate water and other fluid are pumped through the way beyond electric power.Compared with conventional infusion pump,condensate water control pump is very suitable for transmission of "Difficult"medium,such as high temperature condensate water or corrosive fluid.Pressure controlled pump,particular in condensate water automatic pump,are recognized as long-life pump with seldom maintenance needed.The pump is five to ten times the life of traditional ones due to its absence of electromotor, pump impeller and rotary seal structure,at the same time,general maintenance of it will be saved dramatically.

1、It's necessary to return high-temp condensate water into boiler,in order to save boiler water supply and chemical treating agent,and reduce boiler water supply and the cost of reheating.
2、No need to carry out electrical maintenance.
3、It could be used safely in dangerous and explosive environment.
4、It may be used in gauge pressure with capacity from 5 to 250 Psig(1.72MPa)according to different types,and compressed air or other air operation and control.
5、Lyophobe may reach maximum volume of 48,000 pounds/hour(22,000Kg/hr)

Operation

    Condensate water automatic pump discharges liquid by depending on steam or compressed air.Float ball will be linked to connecting rod and spring,simultaneously,drive intake valve and exhaust valve.The intake value will shut down during circulation of liquid charging,at the same time,exhaust valve will open,enabling condensate water into the pump.As the float ball rise with the liquid up to the peak of its journey,the switch control system will set spring free and open intake valve,as well as close exhaust valve.Steam and compressed air subsequently flow into pump and discharge liquid.The check valve that fixed at intake of exhaust of pump will drive the liquid flowing in opposite path.

Characteristic

    Lyophobe capacity is determined by several parameters.The thing to be noticed is the fact that it's discontinuous liquid that condensate water automatic pump released is,the amount of liquid discharging should rest with the speed of circulation.The size of driving pressure and resistance of flowing path are distinct elements and limiting factors,Secondly,it should be attributable to some factors,such as CV value of check valve,the pressure or head of charging liquid,resistance of exhaust pipe,and characteristic of driving gas.

    Automatic pump only has entrance side,and no"Vacuum"side.The key issue is that we shoule be conscious of the fact that such automatic pump in this kind could not pump and suck fluid inside.Medium should flow into the pump in virtue of gravity.The more pressure or hesd is,more bigger the CV value of check valve is,secondly,more bigger the CV value of exhaust valve is,the more faster the pace of completion of side circulation will be.Upon completion of liquid charging,control system will shun down exhaust valve and open intake valve.At the moment,steam and compressed gas will expel the liquid from pump.There are some factors influencing velocity of cicle discharging of liquid,including driving the pressure of steam or air,CV value of check valve of exit back valve,downstream back pressure,along with possibility of flowing medium and temperature of surroundings(In case of taking steam as driving air),The last factor is often ignored,but the fact is that steam will be condensed,therefore,reduce actual driving pressure,such phenomenon could be very serious on some applications.



Basic principle
    The condensate control pump belongs to a pressure control pump and is mainly designed for situations where electricity is not applied to pump condensate or other fluids. Compared with the traditional water pump, the condensate control pump is especially suitable for the "difficult" medium, such as high temperature condensate water or corrosive fluid. Pressure operated pumps, especially condensate control pumps, are recognized as long - lived, rarely - maintained pumps. Because the pump has no rotary seal structure, no motor and pump impeller, the service life is usually five to ten times of the traditional electric pump, and at the same time, most of the general maintenance is omitted.
    1, the high temperature condensate is sent back to the boiler, the chemical treatment agent of boiler water supply is saved, and the cost of reheating the feed water of the manufacturing material boiler is reduced.
    2, the pump does not need electrical maintenance.
    3, the pump can be safely used in dangerous or explosive environments.
    4. According to the different models, the steam, compressed air or other gas can be controlled by the pressure of 0.5 to 1.6Mpa.
    5. The maximum amount of water thinning up to 22000Kg/h.
    The condensate control pump is discharged from the steam or compressed gas. The floating ball is connected to the connecting rod and the spring, and the intake valve and the exhaust valve are also driven. In the liquid filling cycle, the intake valve is closed and the exhaust valve opens, so that the condensate is filled into the pump body. When the floating ball rises with the level of the liquid level to the point of its stroke, the switch control mechanism opens the spring, opens the intake valve, and closes the exhaust valve. Steam or compressed gas flow into the pump and discharge the liquid. A reverse check valve is installed at the inlet and outlet of the pump to make the liquid flow in the direction of the reverse check valve.


外形尺寸 Shape size


接口

Interface

外形尺寸Shape size(mm)

重量kg


A

B

C

D

E

F


1* 1

879

140

152

641

457

635

79

1-1/2*

 1-1/2

933

140

152

641

457

635

81

2* 2

943

140

152

641

457

635

83

3* 2

971

140

152

641

457

635

86






Installation and start operation
install
1, the installation location of condensate control pump should ensure that all upstream condensate discharged into the pump can be discharged smoothly, and the recommended inlet pressure head is 12 "(305mm), which can correctly introduce operation steam or compressed air.
2, in the operation of steam, above the pipeline interface must be located in the operation of a steam main pipe, is prohibited under the main pipe is arranged on the main pipeline, to avoid water and impurities into the operation of the steam pipe.
3, if the condensate pump control is used to recover the more hydrophobic point discharge condensate, taking into account the different hydrophobic point exhaust condensation water have different residual pressure, to prevent the mutual interference 
between different hydrophobic, suggested in the condensed water control pump installed before the water collecting tank, collecting tank size is opinion table.
4. The check valve must be installed in the inlet and outlet of the condensate control pump to ensure the normal operation of the condensate control pump. It is suggested that the check valve provided by our company should be used to ensure the drainage of the pump.
5. The installation of the condensate control pump for the open system is shown in the diagram.
6, the total weight of the water pump to control the setting in place carrying capacity is greater than the full of the ground. The surface of the foundation should be smooth and clean.
7, before condensing water enters and enters the condensate control pump, the pipeline of the system must be swept away, so as to avoid contaminants in the system, such as welding slag and rust, and enter the condensate control pump, which will damage the components of the pump body and affect the normal operation of the pump.


Start-up
Check and determine that all joints are connected tightly and start to run.
1. for steam operation occasions, drain pipeline valve to open the steam inlet side, the condensed water pipe emptying out after the valve is closed until the steam.
2. open the outlet valve and exhaust valve.
3. slowly open the condensate inlet valve, fill the pump with water until the more gentle sound of water filling, the entrance valve is completely opened.



常见故障排除Common troubleshooting




问题分析problem analysis

排除方法Elimination method

1. 结水在某水罐内积存,进不了泵内。

water is accumulated in a water tank and can not enter the pump.

a.进水阀未开water inlet valve closed

b.排气阀未开exhaust valve closed

c.罐内已充满水can be filled with water

d.进口止回阀未开inlet check valve open

a.打开进水阀Open the inlet valve

b.打开排汽阀Open exhaust valve

c.检查操作汽是否通入泵内,步骤同故障现象2的方法Check whether the operating steam is put into the pump, the method is the same as the failure phenomenon 2.

2.凝结水泵不排水Undrained condensate pump

a.操作汽未进到泵内Operating steam not into the pump

b.出口止回阀未打开Exit check valve unopened

c.泵内浮球机构未动作Floating ball mechanism in pump

 

a.检查动力汽是否供到泵处,检查泵的进汽口是否被污物堵塞Check whether the power steam is supplied to the pump and check whether the inlet of the pump is blocked by dirt

b.打开泵盖,看浮球是否上下动作自如,并将进、排汽阀切换打开,关闭,排除动作阻碍因素Open the lid of the pump to see if the floating ball moves freely and up and down, and switches the inlet and exhaust valves to open, close, and exclude the impediments of the movement.

c.将出口口止回阀打开,察看其动作情况,去除污等,使其动作无障碍Open the exit check valve, look at its action, remove pollution and so on, so that the action is no obstacle.